Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 23, 2021, 09:30 AM
  • H 0241A_H 0241_08232021_024023.mp4

Date
08/23/2021
W/O
906511
Weather
Dry
Operator/Surveyor
S, LOPEZ
Sewer ID
Z00171
PipeID
P10661
Time
2:30 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9242
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_906511_TV02170_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 0241
Downstream MH
H 0241A
Dir. of Survey
Upstream
Length Surveyed
314.6 ft.
Total Length
314.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
413K
O&M Rating
190
Overall Index
3
Overall Quick
Overall Rating
190
Pipe schematic from manhole H 0241 to H 0241A
MH: H 0241MH: H 0241Aupstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - H 0241A2.8 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish105.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"149.6 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"206.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"305.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"312.6 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start314.6 ft. MWL - Water Level, 15 %of cross sectional area314.6 ft. AMH - Downstream Manhole, Survey Begins - H 0241314.6 ft. MWM - Water Mark, 50 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    9.2 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • General Observation - COCKROACHES IN MANHOLE

    314.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (12)

DistanceCodeObservation
165TBA
209.3TFC
314.6MGOCOCKROACHES IN MANHOLE
9.2TFC
2DAGS
107.7TFA
314.6MGOCONNECTION AT MH 3 O'CLOCK
0MWL
0AMHH 0241
0MWM
314.6AMHH 0241A
311.8DAGS

Properties (7)

additional_info
630069082321001
custom_field_three
GREASE
custom_field_two
3
customer
1
datetime
2021-08-23T02:30:11-07:00
documentation
PRO PIPE
is_lateral_inspection
false