Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2021, 07:01 AM
  • H 0256_H 0255_08202021_001310.mp4

Date
08/20/2021
W/O
906511
Weather
Dry
Operator/Surveyor
S, LOPEZ
Sewer ID
Z00171
PipeID
P10679
Time
12:01 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9241
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_906511_TV02170_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 0256
Downstream MH
H 0255
Dir. of Survey
Downstream
Length Surveyed
396.3 ft.
Total Length
396.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2O00
O&M Rating
156
Overall Index
2
Overall Quick
Overall Rating
159
Pipe schematic from manhole H 0256 to H 0255
MH: H 0256MH: H 0255downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 02560 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start92 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"100 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"161.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"169.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"235.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"252.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"309.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"324.9 ft. FS - Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES392.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish396.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE396.3 ft. AMH - Downstream Manhole, Survey Ends - H 0255

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES

    324.9 ft. - Fracture Spiral, from 06 to 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    396.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
396.3MGOCOCKROACHES IN MANHOLE
0MWL
235.7TFC
2DAGS
92TFC
169.4TFC
252.4TFC
100TFC
0AMHH 0256
161.9TF
0MWM
0MGOCOCKROACHES IN MANHOLE
392.7DAGS
396.3AMHH 0255
324.9FS
309.4TFC
317.7TF

Properties (7)

additional_info
630069081921201
custom_field_three
GREASE, FRACTURE SPIRAL
custom_field_two
3
customer
1
datetime
2021-08-20T00:01:22-07:00
documentation
PRO PIPE
is_lateral_inspection
false