Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2021, 07:39 AM
  • H 0254_H 0253_08202021_005059.mp4

Date
08/20/2021
W/O
906511
Weather
Dry
Operator/Surveyor
S, LOPEZ
Sewer ID
Z00171
PipeID
P10677
Time
12:39 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9241
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_906511_TV02170_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 0253
Downstream MH
H 0254
Dir. of Survey
Upstream
Length Surveyed
254.3 ft.
Total Length
254.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
423I
O&M Rating
155
Overall Index
3
Overall Quick
Overall Rating
155
Pipe schematic from manhole H 0253 to H 0254
MH: H 0253MH: H 0254upstream0 ft. MSA - Survey Abandoned - DUE TO GREASE0 ft. DAGS - Deposits Attached Grease, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish4.9 ft. DAGS - Deposits Attached Grease, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start4.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"4.9 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish29.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"66.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"100.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"119.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"156 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"169.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"197.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"199.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"252.3 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start254.3 ft. MWM - Water Mark, 40 %of cross sectional area254.3 ft. AMH - Downstream Manhole, Survey Begins - H 0253254.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE254.3 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 30 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    249.4 ft. - Deposits Attached Grease, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - DUE TO GREASE

    254.3 ft. - Survey Abandoned - DUE TO GREASE

Observations (19)

DistanceCodeObservation
0MWM
147.7TBA
85.1TFC
249.4DAGS
98.3TF
254.3MSADUE TO GREASE
249.4TFA
0AMHH 0253
2DAGS
55.2TB
0MGOCOCKROACHES IN MANHOLE
134.8TB
0MWL
249.4DAGS
153.6TFC
254.3DAGS
56.8TFC
187.4TF
224.4TF

Properties (7)

additional_info
630069081921201
custom_field_three
GREASE, REVERSAL COMPLETED
custom_field_two
3
customer
1
datetime
2021-08-20T00:39:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false