Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2021, 08:07 AM
  • H 0252_H 0251_08202021_012922.mp4

Date
08/20/2021
W/O
906511
Weather
Dry
Operator/Surveyor
S, LOPEZ
Sewer ID
Z00171
PipeID
P10675
Time
1:07 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9241
Sewer Name
H JOINT OUTFALL H - UNIT 2F
City
VERNON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_906511_TV02170_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
H 0252
Downstream MH
H 0251
Dir. of Survey
Downstream
Length Surveyed
338.3 ft.
Total Length
338.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3L00
O&M Rating
201
Overall Index
3
Overall Quick
Overall Rating
201
Pipe schematic from manhole H 0252 to H 0251
MH: H 0252MH: H 0251downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - H 02522 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start76.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"79.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"175.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"179.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"277.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"336 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish338.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE338.3 ft. AMH - Downstream Manhole, Survey Ends - H 0251

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    338.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (14)

DistanceCodeObservation
277.9TFC
0MWL
0MWM
179.2TFA
175.9TF
79.8TFC
2DAGS
336DAGS
0MGOCOCKROACHES IN MANHOLE
338.3MGOCOCKROACHES IN MANHOLE
0AMHH 0252
275.6TFA
338.3AMHH 0251
76.8TFC

Properties (7)

additional_info
630069081921201
custom_field_three
GREASE
custom_field_two
3
customer
1
datetime
2021-08-20T01:07:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false