- Date
- 08/09/2021
- W/O
- 906781
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00887
- PipeID
- P25347
- Time
- 3:34 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9226
- Sewer Name
- 32 DISTRICT #32 MAIN TRUNK
- City
- VALENCIA
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 32
- Page No.
- 08
- Purpose
- Resurvey For Any Reason
- Project
- WO_906781_TV32015_AUG2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- 32 0113
- Downstream MH
- 32 0112A
- Dir. of Survey
- Downstream
- Length Surveyed
- 358 ft.
- Total Length
- 358 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 180
- O&M Index
- 2
- O&M Quick
- 2700
- O&M Rating
- 14
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 194
Pipe schematic from manhole 32 0113 to 32 0112A Observation photos (2)

13.1 ft. - Roots Fine Barrell, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

53.4 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start