Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2021, 09:46 AM
  • 32 1339_32 0116_08092021_025459.mp4

Date
08/09/2021
W/O
906781
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19862
Time
2:46 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9226
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
VALENCIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_906781_TV32015_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
32 0116
Downstream MH
32 1339
Dir. of Survey
Upstream
Length Surveyed
246.4 ft.
Total Length
246.4 ft.
Structural Index
4
Structural Quick
5E3H
Structural Rating
281
O&M Index
3
O&M Quick
3I00
O&M Rating
147
Overall Index
3
Overall Quick
Overall Rating
428
Pipe schematic from manhole 32 0116 to 32 1339
MH: 32 0116MH: 32 1339upstream0 ft. AMH - Upstream Manhole, Survey Ends - 32 13390 ft. MGO - General Observation - STOP LOG AT MOUTH OF PIPE.0.9 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish0.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish142.5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish142.5 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start142.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start237.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start244.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - DEBRIS244.4 ft. MGO - General Observation - MAG COATING THROUGHOUT246.4 ft. AMH - Downstream Manhole, Survey Begins - 32 1339246.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE246.4 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (6)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Settled Other,  15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start - DEBRIS

    2 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - DEBRIS

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    103.9 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    103.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0AMH32 1339
245.5SRV
246.4AMH32 1339
245.5SAP
2DSZDEBRIS
9.3SAV
0MGOCOCKROACHES IN MANHOLE
103.9SAV
103.9SRV
246.4MGOSTOP LOG AT MOUTH OF PIPE.
245.5DSZ
103.9SAP
0MWL
2MGOMAG COATING THROUGHOUT

Properties (7)

additional_info
630069080921001
custom_field_three
VISIBLE REINFORCEMENT/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2021-08-09T02:46:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false