Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2021, 10:12 AM
  • 02 2009_02 2008_08062021_032925.mp4

Date
08/06/2021
W/O
906747
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00239
PipeID
P04363
Time
3:12 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9224
Sewer Name
02 BELVEDERE RELIEF TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_906747_TV02020_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
8 in.
Upstream MH
02 2009
Downstream MH
02 2008
Dir. of Survey
Downstream
Length Surveyed
508.3 ft.
Total Length
508.3 ft.
Structural Index
3
Structural Quick
3T00
Structural Rating
309
O&M Index
2
O&M Quick
2[00
O&M Rating
282
Overall Index
2
Overall Quick
Overall Rating
591
Pipe schematic from manhole 02 2009 to 02 2008
MH: 02 2009MH: 02 2008downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 20090 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 65% MAG COAT305.5 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS506 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish506 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish506.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish506.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish508.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN508.3 ft. AMH - Downstream Manhole, Survey Ends - 02 2008508.3 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE508.3 ft. MGO - General Observation - ROACHES @ MH

Observation photos (4)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - 65% MAG COAT

    2 ft. - General Observation - 65% MAG COAT

  • General Observation - ROACHES @ MH

    508.3 ft. - General Observation - ROACHES @ MH

Observations (17)

DistanceCodeObservation
508.3MGOCONN @ MH 3 O'CLOCK/OPEN
0AMH02 2009
2SAV
2DAGS
0MGOROACHES @ MH
508.3AMH02 2008
2SAV
506SAV
506.3DAGS
506SAV
508.3MGOCONN @ MH 9 O'CLOCK/ACTIVE
2MGO65% MAG COAT
305.5DSZDEBRIS
0MWL
508.3MGOROACHES @ MH
0MWM
506.3DSZ

Properties (8)

additional_info
630069080521203
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-08-06T03:12:49-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27592