Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 07:12 AM
  • 20 0663_20 0662_07132021_002935.mp4

Date
07/13/2021
W/O
901265
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01139
PipeID
P25442
Time
12:12 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9029
Sewer Name
20 35TH STREET EAST RELIEF TRUNK
City
PALMDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 20
Page No.
08
Purpose
Routine Assessment
Project
WO_901265_TV20048_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
20 0663
Downstream MH
20 0662
Dir. of Survey
Downstream
Length Surveyed
451.7 ft.
Total Length
451.7 ft.
Structural Index
3
Structural Quick
3A00
Structural Rating
30
O&M Index
2
O&M Quick
2b00
O&M Rating
354
Overall Index
2
Overall Quick
Overall Rating
384
Pipe schematic from manhole 20 0663 to 20 0662
MH: 20 0663MH: 20 0662downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 20 06630 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start14.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start - MINERAL DEPOSITS116.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES117.6 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"121.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start168.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish449.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish449.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish451.7 ft. AMH - Downstream Manhole, Survey Ends - 20 0662

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start - MINERAL DEPOSITS

    14.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start - MINERAL DEPOSITS

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    116.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    121.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
116.1CM
451.7AMH20 0662
0MWM
0AMH20 0663
14.4DAEMINERAL DEPOSITS
449.6DAGS
117.6TFA
2DAGS
121.5CM
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
449.6DAE
168.3CM

Properties (8)

additional_info
630069071221201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-07-13T00:12:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
38677