Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 18, 2021, 12:13 PM
  • H 0948_H 0947_08182021_054238.mp4

Date
08/18/2021
W/O
906779
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01005
PipeID
P15361
Time
5:13 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9257
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_906779_TV21087_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
H 0947
Downstream MH
H 0948
Dir. of Survey
Upstream
Length Surveyed
500.6 ft.
Total Length
500.7 ft.
Structural Index
3
Structural Quick
3S2S
Structural Rating
495
O&M Index
2
O&M Quick
2W00
O&M Rating
236
Overall Index
2
Overall Quick
Overall Rating
731
Pipe schematic from manhole H 0947 to H 0948
MH: H 0947MH: H 0948upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 09482 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish53.1 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"147.7 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"230.3 ft. DAR - Deposits Attached Ragging, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO354 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"412.5 ft. DAR - Deposits Attached Ragging, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish498.6 ft. MGO - General Observation - 65% MAG COAT498.6 ft. DAR - Deposits Attached Ragging, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start498.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - UNDER MAG COATING498.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start498.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start500.7 ft. AMH - Downstream Manhole, Survey Begins - H 0947500.7 ft. MWM - Water Mark, 15 %of cross sectional area500.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/OPEN500.7 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - UNDER MAG COATING

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - UNDER MAG COATING

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Ragging, 10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Ragging, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Ragging, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: NO

    270.4 ft. - Deposits Attached Ragging, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO

Observations (18)

DistanceCodeObservation
498.7SAV
270.4DAR
146.7TFA
0AMHH 0947
2SSSUNDER MAG COATING
2DAGS
353TBA
2.1MGO65% MAG COAT
2SAV
447.6TBC
498.7SSS
0MWM
88.2DAR
0MGOCONN @ MH 9 O'CLOCK/OPEN
2.1DAR
500.7AMHH 0948
498DAGS
0MWL

Properties (7)

additional_info
630138081821022
custom_field_three
AGGREGATE VISIBLE, SPALLING
custom_field_two
3
customer
1
datetime
2021-08-18T05:13:32-07:00
documentation
PROPIPE
is_lateral_inspection
false