Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2021, 04:46 AM
  • H 0995_A 1102_08122021_215421.mp4

Date
08/12/2021
W/O
906779
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01005
PipeID
P15410
Time
9:46 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9117
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_906779_TV21087_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
A 1102
Downstream MH
H 0995
Dir. of Survey
Upstream
Length Surveyed
5.1 ft.
Total Length
5.1 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole A 1102 to H 0995
MH: A 1102MH: H 0995upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 09950 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE3.1 ft. MGO - General Observation - 60% MAG COAT3.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES5.1 ft. MWL - Water Level, 20 %of cross sectional area5.1 ft. MWM - Water Mark, 50 %of cross sectional area5.1 ft. AMH - Downstream Manhole, Survey Begins - A 1102

Observation photos (2)

  • General Observation - 60% MAG COAT

    2 ft. - General Observation - 60% MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
2MGO60% MAG COAT
0MWL
5.1AMHH 0995
5.1MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWM
0AMHA 1102
2SSS

Properties (7)

additional_info
630138081221201
custom_field_three
MAG COAT, SPALLING
custom_field_two
3
customer
1
datetime
2021-08-12T21:46:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false