Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2021, 07:05 AM
  • H 0991_H 0990_08132021_002351.mp4

Date
08/13/2021
W/O
906779
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01005
PipeID
P15405
Time
12:05 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9117
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_906779_TV21087_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
H 0991
Downstream MH
H 0990
Dir. of Survey
Downstream
Length Surveyed
456.2 ft.
Total Length
456.2 ft.
Structural Index
3
Structural Quick
3Q2Q
Structural Rating
447
O&M Index
2
O&M Quick
2Q00
O&M Rating
182
Overall Index
2
Overall Quick
Overall Rating
629
Pipe schematic from manhole H 0991 to H 0990
MH: H 0991MH: H 0990downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH0 ft. AMH - Upstream Manhole, Survey Begins - H 09910 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. MGO - General Observation - 55% MAG COAT7.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start55.2 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"158.5 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"270.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN375.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN453.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish453.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish454 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish456 ft. MGO - General Observation - ROACHES @ MH456.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/OPEN456.2 ft. AMH - Downstream Manhole, Survey Ends - H 0990456.2 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED

Observation photos (7)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 55% MAG COAT

    2.6 ft. - General Observation - 55% MAG COAT

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    55.2 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    158.5 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    270.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    375.4 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

Observations (19)

DistanceCodeObservation
454DAGS
158.5TBC
270.7TBOPEN
0MWM
2.6SSS
453.2SAV
0MGOROACHES @ MH
375.4TBOPEN
456MGOROACHES @ MH
55.2TBA
456.2MGOCONN @ MH 3 O'CLOCK/OPEN
456.2AMHH 0990
0AMHH 0991
456.2MGOCONN @ MH 9 O'CLOCK/CAPPED
2.6MGO55% MAG COAT
2DAGS
0MWL
453.2SSS
7.6SAV

Properties (7)

additional_info
630138081221201
custom_field_three
MAG COAT, SPALLING, AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-08-13T00:05:02-07:00
documentation
PRO PIPE
is_lateral_inspection
false