Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 2, 2021, 12:11 PM
  • 29 0507A_29 0507_08022021_052326.mp4

Date
08/02/2021
W/O
901244
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P24557
Time
5:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9091
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_901244_TV29015_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0507A
Downstream MH
29 0507
Dir. of Survey
Downstream
Length Surveyed
239.5 ft.
Total Length
239.5 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
137
Pipe schematic from manhole 29 0507A to 29 0507
MH: 29 0507AMH: 29 0507downstream0 ft. AMH - Upstream Manhole, Survey Begins - 29 0507A0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"5.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"14.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.3 ft. MGO - General Observation - PIPE IS NRCP40 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"43 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"58 ft. DSGV - Deposits Settled Gravel, 10 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: NO58.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"117.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"185 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"233.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"235.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"236.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"239.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK239.5 ft. AMH - Downstream Manhole, Survey Ends - 29 0507239.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    5.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

    236.7 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"

Observations (21)

DistanceCodeObservation
239.5MGOCONNECTION AT THE MH 9 OC'LOCK
117.6TF
58DSGV
2.7TFC
0AMH29 0507A
239.5AMH29 0507
235.6TF
185TF
14.3SAV
236.7TB
63.7TFC
5.1TB
58.2TF
210.9TF
239.5SAV
233.5TFC
40TF
0MWM
14.3MGOPIPE IS NRCP
0MWL
43TFC

Properties (7)

additional_info
630074080221022
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-08-02T05:11:21-07:00
documentation
PROPIPE
is_lateral_inspection
false