Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 4, 2021, 04:38 AM
  • 29 0823_29 0464_08032021_214959.mp4

Date
08/03/2021
W/O
901244
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P25792
Time
9:38 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9093
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_901244_TV29015_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0823
Downstream MH
29 0464
Dir. of Survey
Downstream
Length Surveyed
296.1 ft.
Total Length
296.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 29 0823 to 29 0464
MH: 29 0823MH: 29 0464downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 08237.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"9.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"42.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"122.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"185.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"244.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"296.1 ft. AMH - Downstream Manhole, Survey Ends - 29 0464296.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (5)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    122.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    128.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    181.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    185.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    244.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (15)

DistanceCodeObservation
296.1AMH29 0464
7.4TFC
181.3TB
150.3TFC
122.9TB
296.1MGOCONNECTION AT THE MH 3 OC'LOCK
0MWL
128.7TB
185.8TB
0MWM
244.4TB
152.3TFC
0AMH29 0823
42.3TF
9.5TFC

Properties (7)

additional_info
630074080321201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-08-03T21:38:43-07:00
documentation
PROPIPE
is_lateral_inspection
false