Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2021, 08:23 AM
  • 18 0637_18 0636_06282021_013712.mp4

Date
06/28/2021
W/O
896146
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00692
PipeID
P14488
Time
1:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9057
Sewer Name
18 NORTH PLANT OUTFALL RELIEF TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_896146_TV18085_JUN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0637
Downstream MH
18 0636
Dir. of Survey
Downstream
Length Surveyed
284.8 ft.
Total Length
284.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0637 to 18 0636
MH: 18 0637MH: 18 0636downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 06370 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area284.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0636

Observations (5)

DistanceCodeObservation
0AMH18 0637
0MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
0MWL
284.8AMH18 0636

Properties (7)

additional_info
630074062821001
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-06-28T01:23:15-07:00
documentation
PROPIPE
is_lateral_inspection
false