Wastewater/Activity/PacpInspection/1.0Sep 8, 2021, 09:26 AM
  • B 0766_B 0765_09082021_024721.mp4

Date
09/08/2021
W/O
911403
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00112
PipeID
P09233
Time
2:26 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9124
Sewer Name
B JOINT OUTFALL B - UNIT 8J
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_911403_TV15210_SEP2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
24 in.
Upstream MH
B 0766
Downstream MH
B 0765
Dir. of Survey
Downstream
Length Surveyed
598.9 ft.
Total Length
598.9 ft.
Structural Index
3
Structural Quick
3W2W
Structural Rating
595
O&M Index
2
O&M Quick
2W00
O&M Rating
238
Overall Index
2
Overall Quick
Overall Rating
833
Pipe schematic from manhole B 0766 to B 0765
MH: B 0766MH: B 0765downstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 07662 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 75% MAG COAT33.8 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 4", 8"38.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"205.2 ft. TFB - Tap Factory Made Abandoned, at 01 o'clock, -, within 8 inches of joint: YES, 4", 6"209.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"303.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"360.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"400.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"408.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 8"514.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"595.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish595.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish596 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish598 ft. MGO - General Observation - ROACHES @ MH598.9 ft. AMH - Downstream Manhole, Survey Ends - B 0765

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 75% MAG COAT

    2 ft. - General Observation - 75% MAG COAT

  • Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 4", 8"

    33.8 ft. - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 4", 8"

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"

    38.7 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"

  • Tap Factory Made Abandoned, at 01 o'clock, -, within 8 inches of joint: YES, 4", 6"

    205.2 ft. - Tap Factory Made Abandoned, at 01 o'clock, -, within 8 inches of joint: YES, 4", 6"

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"

    209.3 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

    303.4 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

    400.4 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

  • Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 8"

    408.4 ft. - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4", 8"

  • Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

    514.1 ft. - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 8"

Observations (22)

DistanceCodeObservation
0MGOROACHES @ MH
514.1TFC
205.2TFB
38.7TFC
33.8TFB
598MGOROACHES @ MH
0MWL
2DAGS
303.4TFC
598.9AMHB 0765
408.4TFC
0MWM
595.9SSS
2SSS
2SAV
0AMHB 0766
400.4TFC
360.4TFC
2MGO75% MAG COAT
596DAGS
209.3TFC
595.9SAV

Properties (7)

additional_info
630069090721201
custom_field_three
SPALLING, AGGREGATE VISIBLE, MAG COAT
custom_field_two
3
customer
1
datetime
2021-09-08T02:26:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false