- Date
- 08/18/2021
- W/O
- 906610
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00767
- PipeID
- P20059
- Time
- 3:58 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9256
- Sewer Name
- 21 FIRST ST TR, SECT 1A & CONNS TO 1ST ST TR SYSTM
- City
- POMONA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906610_TV21099_AUG2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 21 0138
- Downstream MH
- 21 1094
- Dir. of Survey
- Downstream
- Length Surveyed
- 16.1 ft.
- Total Length
- 16.2 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 21 0138 to 21 1094 Observation photos (4)

4.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

4.4 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

7.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

7.8 ft. - Surface Reinforcement Visible, from 10 to 03 o'clock, within 8 inches of joint: YES, Start