Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2021, 09:44 AM
  • B 1128_B 1127_07132021_033020.mp4

Date
07/13/2021
W/O
901874
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01125
PipeID
P13168
Time
2:44 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8676
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
ALHAMBRA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_901874_TV16072_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
B 1127
Downstream MH
B 1128
Dir. of Survey
Upstream
Length Surveyed
29.5 ft.
Total Length
29.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3124
O&M Rating
11
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole B 1127 to B 1128
MH: B 1127MH: B 1128upstream0 ft. MSA - Survey Abandoned - REVERSAL COMPLETED0.3 ft. RTJ - Roots Tap Joint, at 02 o'clock, 5 %, within 8 inches of joint: YESR0.3 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish9.7 ft. RTJ - Roots Tap Joint, from 09 to 10 o'clock, 5 %, within 8 inches of joint: YESR20.6 ft. RTL - Roots Tap Lateral, from 10 to 11 o'clock, 5 %20.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"22.5 ft. RTB - Roots Tap Barrell, from 03 to 09 o'clock, 5 %, Finish23.5 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start27.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"27.4 ft. RTB - Roots Tap Barrell, from 03 to 09 o'clock, 5 %, Start - FROM MH29.5 ft. MWL - Water Level, 0 %of cross sectional area29.5 ft. AMH - Downstream Manhole, Survey Begins - B 112729.5 ft. MGO - Reversal Inspection29.5 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (5)

  • Roots Tap Barrell, from 03 to 09 o'clock, 5 %, Start - FROM MH

    2.1 ft. - Roots Tap Barrell, from 03 to 09 o'clock, 5 %, Start - FROM MH

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    6 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Roots Tap Lateral, from 10 to 11 o'clock, 5 %

    8.9 ft. - Roots Tap Lateral, from 10 to 11 o'clock, 5 %

  • Roots Tap Joint, from 09 to 10 o'clock, 5 %, within 8 inches of joint: YESR

    19.8 ft. - Roots Tap Joint, from 09 to 10 o'clock, 5 %, within 8 inches of joint: YESR

  • Roots Tap Joint, at 02 o'clock, 5 %, within 8 inches of joint: YESR

    29.2 ft. - Roots Tap Joint, at 02 o'clock, 5 %, within 8 inches of joint: YESR

Observations (14)

DistanceCodeObservation
29.2RTJ
0MWL
0AMHB 1127
29.2DAE
2.2TF
29.5MSAREVERSAL COMPLETED
0MGO
6DAE
0MWM
8.9RTL
8.9TF
19.8RTJ
2.1RTBFROM MH
7RTB

Properties (7)

additional_info
630138071221201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-07-13T02:44:30-07:00
documentation
PROPIPE
is_lateral_inspection
false