B 1126_B 1125_07202021_033513.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
5.1 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
25.2 ft. - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES
33.8 ft. - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES
54.1 ft. - Crack Spiral, from 09 to 04 o'clock, within 8 inches of joint: YES
81.1 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES
91.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
132.3 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES
180.2 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 180.2 | FL | — |
| 132.3 | FL | — |
| 254.4 | TF | — |
| 209.2 | TF | — |
| 0 | MWM | — |
| 2 | DAGS | — |
| 25.2 | FM | — |
| 195 | TF | — |
| 83 | TF | — |
| 0 | AMH | B 1126 |
| 258.9 | DAGS | — |
| 91.7 | CM | — |
| 54.1 | CS | — |
| 0 | MGO | LIGHT STEAM IN SEWER |
| 259.8 | AMH | B 1125 |
| 206.3 | TB | — |
| 258.9 | CM | — |
| 63.9 | TF | — |
| 0 | MWL | — |
| 159 | TFA | — |
| 72 | TFA | — |
| 81.1 | FL | — |
| 175.1 | TF | — |
| 86.2 | TF | — |
| 33.8 | CM | — |
| 5.1 | CL | — |