Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2018, 09:37 AM
Date
01/25/2018
W/O
684977
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00597
PipeID
P12319
Time
1:37 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5175
Sewer Name
15 ARROYO DRIVE TRUNK
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
31
Purpose
Routine Assessment
Project
WO_684977_TV15013_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
15 0396
Downstream MH
15 0395
Dir. of Survey
Downstream
Length Surveyed
125.5 ft.
Total Length
125.5 ft.
Structural Index
3
Structural Quick
4231
Structural Rating
15
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole 15 0396 to 15 0395
MH: 15 0396MH: 15 0395downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 03960 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start11.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES12.2 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Start14.8 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start21.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish21.1 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES - CIP21.1 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Finish38.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"43.9 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES53.4 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES56.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start71.1 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"83.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"119.4 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4"123.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish123.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish125.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0395

Observations (20)

DistanceCodeObservation
0MWM
83.3TFC
125.5AMH15 0395
123.7FM
71.1TFC
38.5TFC
21.1DAE
0AMH15 0396
11.7CL
0MWL
21.1RPLCIP
12.2MWLS
119.4TFC
21.1MWLS
43.9FM
123.7DAGS
53.4CM
56.6FM
2.1DAGS
14.8DAE

Properties (6)

additional_info
SC347015
custom_field_two
3
customer
LACSD
datetime
2018-01-25T01:37:45-08:00
documentation
PROPIPE
is_lateral_inspection
false