Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2021, 06:21 PM
  • LN 0014_LN 0011_09232021_112937.mp4

Date
09/23/2021
W/O
URGENT
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01232
PipeID
P26759
Time
11:21 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9134
Sewer Name
14 LNWRP PLANT SEWERS
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
01
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
LN 0011
Downstream MH
LN 0014
Dir. of Survey
Upstream
Length Surveyed
173.9 ft.
Total Length
173.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole LN 0011 to LN 0014
MH: LN 0011MH: LN 0014upstream0 ft. AMH - Upstream Manhole, Survey Ends - LN 00141.9 ft. MGO - General Observation - Surface Spalling throughout the reach, from 9 to 3 o'clock61.4 ft. MGO - General Observation - STEAM IN LINE102.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"173.9 ft. MWM - Water Mark, 10 %of cross sectional area173.9 ft. MWL - Water Level, 5 %of cross sectional area173.9 ft. AMH - Downstream Manhole, Survey Begins - LN 0011173.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"

    71.4 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"

  • General Observation - STEAM IN LINE

    112.5 ft. - General Observation - STEAM IN LINE

Observations (8)

DistanceCodeObservation
71.4TBA
112.5MGOSTEAM IN LINE
0MWM
0MWL
0AMHLN 0011
0MGOCONNECTION AT MH 9 O'CLOCK
172MGOSurface Spalling throughout the reach, from 9 to 3 o'clock
173.9AMHLN 0014

Properties (7)

additional_info
630138092321051
custom_field_three
NO STRUCTURAL DEFECTS
custom_field_two
3
customer
1
datetime
2021-09-23T11:21:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false