Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2021, 06:07 PM
  • LN 0012_LN 0011_09232021_111702.mp4

Date
09/23/2021
W/O
URGENT
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01232
PipeID
P26757
Time
11:07 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9134
Sewer Name
14 LNWRP PLANT SEWERS
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
01
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
LN 0011
Downstream MH
LN 0012
Dir. of Survey
Upstream
Length Surveyed
230.7 ft.
Total Length
230.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole LN 0011 to LN 0012
MH: LN 0011MH: LN 0012upstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - LN 00120 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK1.7 ft. MGO - General Observation - Surface Spalling throughout the reach, From 9 to 3 oclock53 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 8"170.7 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 8"230.7 ft. MWM - Water Mark, 20 %of cross sectional area230.7 ft. AMH - Downstream Manhole, Survey Begins - LN 0011230.7 ft. MWL - Water Level, 10 %of cross sectional area230.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (10)

DistanceCodeObservation
229MGOSurface Spalling throughout the reach, From 9 to 3 oclock
60TF
0MWM
0AMHLN 0011
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
177.7TF
230.7MGOCONNECTION AT MH 9 O'CLOCK
230.7AMHLN 0012
230.7MGOCONNECTION AT MH 3 O'CLOCK

Properties (7)

additional_info
630138092321051
custom_field_three
NO STRUCTURAL DEFECTS
custom_field_two
3
customer
1
datetime
2021-09-23T11:07:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false