Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2021, 06:34 PM
  • LN 0011_LN 0010_09232021_114043.mp4

Date
09/23/2021
W/O
URGENT
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01232
PipeID
P26756
Time
11:34 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9134
Sewer Name
14 LNWRP PLANT SEWERS
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
01
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
LN 0011
Downstream MH
LN 0010
Dir. of Survey
Downstream
Length Surveyed
172.8 ft.
Total Length
172.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole LN 0011 to LN 0010
MH: LN 0011MH: LN 0010downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - LN 001163.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"82.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"171 ft. MGO - General Observation - Surface Spalling throughout the reach, from 9 to 3 o'clock172.8 ft. AMH - Downstream Manhole, Survey Ends - LN 0010

Observations (8)

DistanceCodeObservation
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
171MGOSurface Spalling throughout the reach, from 9 to 3 o'clock
172.8AMHLN 0010
63.9TF
82.9TF
0AMHLN 0011

Properties (7)

additional_info
630138092321051
custom_field_three
NO STRUCTURAL DEFECTS
custom_field_two
3
customer
1
datetime
2021-09-23T11:34:33-07:00
documentation
PRO PIPE
is_lateral_inspection
false