G 0315_G 0314_9232021_025628.mp4
2 ft. - General Observation - 95% MAG COAT START
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED MISSING
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - 50% MISSING TILES START
37.4 ft. - Deposits Settled Other, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - MISSING TILES UNDER FLOW
37.4 ft. - General Observation - NEW MISSING TILE AREA
55.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR CORRDED MISSING
97.2 ft. - General Observation - 3 NEW MISSING TILES
133 ft. - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
143.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR CORRODED BROKEN MISSING
182.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN CIRCUM REBAR
203.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING HANGING REBAR
260.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - MISSING BROKEN REBSR
292.8 ft. - Surface Reinforcement Corroded, at 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR CORRODED
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 2 | MGO | 95% MAG COAT START |
| 309 | MGO | 95% MAG COAT FINISH |
| 2 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 0 | MWL | — |
| 97.2 | MGO | 3 NEW MISSING TILES |
| 309 | SSS | BLISTERING PEELING CONCRETE |
| 309 | MGO | 75% MISSING TILES FINISH |
| 182.2 | MGO | 75% MISSING TILES START |
| 180.2 | DSZ | MISSING TILES UNDER FLOW |
| 182.2 | SRC | BROKEN CIRCUM REBAR |
| 143.6 | SRC | LONG CIRCUM REBAR CORRODED BROKEN MISSING |
| 0 | AMH | 3:10AM |
| 309 | SRC | LONG CIRCUM REBAR CORRODED BROKEN MISSING |
| 37.4 | DSZ | MISSING TILES UNDER FLOW |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 2 | SAM | SEVERE AGG |
| 260.6 | SRC | MISSING BROKEN REBSR |
| 133 | SRC | CIRCUM REBAR |
| 292.8 | SRC | CIRCUM REBAR CORRODED |
| 37.4 | MGO | NEW MISSING TILE AREA |
| 0 | AMH | 3:50AM |
| 55.1 | SRC | CIRCUM REBAR CORRDED MISSING |
| 203.2 | SRC | BROKEN MISSING HANGING REBAR |
| 2 | MGO | 50% MISSING TILES START |
| 309 | SAM | SEVERE AGG |