01 0920_01 0918_9222021_013709.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - General Observation - MAG COAT 80% START
2 ft. - General Observation - MISSING TILES 30% START
30 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
32.3 ft. - General Observation - 60% MISSING TILES START
54.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
61 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED MISSING
63.3 ft. - General Photograph - CORRODED REBAR
67.8 ft. - General Observation - NEW MISSING TILE AREA
131.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 2 | SAM | SEVERE AGG |
| 170.2 | SRC | LONG CIRCUM REBAR CORRODED |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 61 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 0 | AMH | 1:45AM |
| 2 | MGO | MAG COAT 80% START |
| 30 | SAM | SEVERE AGG |
| 170.2 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 54.9 | SRC | LONG CIRCUM REBAR |
| 67.8 | MGO | NEW MISSING TILE AREA |
| 2 | MGO | MISSING TILES 30% START |
| 170.2 | SSS | BLISTERING PEELING CONCRETE |
| 63.3 | MGP | CORRODED REBAR |
| 0 | MWL | — |
| 0 | MWM | — |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 170.2 | MGO | 60% MISSING TILES FINISH |
| 131.2 | SRC | CIRCUM REBAR |
| 32.3 | MGO | 60% MISSING TILES START |
| 170.2 | SAM | SEVERE AGG |
| 170.2 | MGO | 80% MAG COAT FINISH |