- Date
- 09/27/2021
- W/O
- 0916327
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00035
- PipeID
- P10154
- Time
- 3:08 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1956
- Sewer Name
- F JOINT OUTFALL F - UNIT 3A
- City
- BELLFLOWER
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210925MDM_JOINT_OUTFALL_F_UNIT_3A
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Upstream MH
- F 0069
- Downstream MH
- F 0068
- Dir. of Survey
- Downstream
- Length Surveyed
- 358.8 ft.
- Total Length
- 358.8 ft.
- Structural Index
- 4
- Structural Quick
- 5143
- Structural Rating
- 19
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 23
Pipe schematic from manhole F 0069 to F 0068 Observation photos (6)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

164.9 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

235.6 ft. - General Observation - 5% MAG COAT TOP OF PIPE

332.5 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

352.8 ft. - Surface Reinforcement Corroded, at 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR