G 0321_G 0320_9212021_040459.mp4
0 ft. - Water Mark, 50 %of cross sectional area
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - 70% MAG COAT
2 ft. - General Observation - 50% MISSING TILES START
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
13.7 ft. - General Observation - 100% MISSING TILES UNDER MAG COAT
39 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR CORRODED BROKEN
89.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
101.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR CORRODED BROKEN MISSING
113.7 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
144.1 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
167.5 ft. - General Observation - 20% MISSING TILES START
201.8 ft. - General Observation - 100% MISSING TILES
217.1 ft. - General Observation - 50% MISSING TILES START
294.1 ft. - General Observation - NEW MISSING TILE AREA
| Distance | Code | Observation |
|---|---|---|
| 2 | SAM | SEVERE AGG |
| 0 | MWL | — |
| 101.1 | SRC | LONG CIRCUM REBAR CORRODED BROKEN MISSING |
| 352.1 | MGO | 50% MISSING TILES FINISH |
| 352.1 | SRC | LONG CIRCUM REBAR CORRODED BROKEN MISSING |
| 352.1 | SAM | SEVERE AGG |
| 89.7 | SRC | CIRCUM REBAR |
| 217.1 | MGO | 50% MISSING TILES START |
| 2 | MGO | 70% MAG COAT |
| 113.7 | SRC | CIRCUM REBAR |
| 144.1 | SAM | SEVERE AGG |
| 46.2 | DSZ | MISSING TILES UNDER FLOW |
| 352.6 | AMH | 4:50AM |
| 2 | MGO | 50% MISSING TILES START |
| 0 | AMH | 4:05AM |
| 294.1 | MGO | NEW MISSING TILE AREA |
| 0 | MWM | — |
| 352.1 | SRC | CORRODED MISSING CIRCUM REBAR |
| 352.1 | MGO | 70% MAG COAT FINISH |
| 39 | SRC | CIRCUM REBAR CORRODED BROKEN |
| 352.1 | DSZ | MISSING TILES UNDER FLOW |
| 167.5 | MGO | 20% MISSING TILES START |
| 352.1 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 201.8 | MGO | 100% MISSING TILES |
| 13.7 | MGO | 100% MISSING TILES UNDER MAG COAT |
| 352.1 | MGO | 50% MISSING TILES FINISH |
| 352.1 | SSS | BLISTERING PEELING CONCRETE |
| 352.1 | MGO | Conn. @ Mh, 3 O' Clock. OPEN |
| 2 | SSS | BLISTERING PEELING CONCRETE |