Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2021, 07:30 AM
  • G 0086_G 0016_9162021_014919.mp4

Date
09/16/2021
W/O
0901312
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P02220
Time
12:30 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1943
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20210913MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0086
Downstream MH
G 0016
Dir. of Survey
Downstream
Length Surveyed
8.3 ft.
Total Length
8.3 ft.
Structural Index
4
Structural Quick
5341
Structural Rating
21
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
25
Pipe schematic from manhole G 0086 to G 0016
MH: G 0086MH: G 0016downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active LARGE IN COMING0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:50AM0 ft. MWL - Water Level, 40 %of cross sectional area2 ft. MGO - General Observation - 90% TILES MISSING5.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR CORRODED & MISSING5.5 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, - SEVERE AGG5.5 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, - BLISTERING PEELING CONCRETE7.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR TOP OF STRUCTURE7.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO8.3 ft. AMH - Downstream Manhole, Survey Ends - 2:05AM

Observation photos (6)

  • General Observation - 90% TILES MISSING

    2 ft. - General Observation - 90% TILES MISSING

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES,  - LONG CIRCUM REBAR CORRODED & MISSING

    5.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR CORRODED & MISSING

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES,  - SEVERE AGG

    5.5 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES,  - BLISTERING PEELING CONCRETE

    5.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR TOP OF STRUCTURE

    7.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR TOP OF STRUCTURE

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

    7.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO

Observations (11)

DistanceCodeObservation
5.5SRCLONG CIRCUM REBAR CORRODED & MISSING
0MGOConn. @ Mh, 3 O' Clock. Active LARGE IN COMING
5.5SAMSEVERE AGG
7.2SRCBROKEN REBAR TOP OF STRUCTURE
0MWM
8.3AMH2:05AM
0AMH1:50AM
0MWL
2MGO90% TILES MISSING
7.2SRC
5.5SSSBLISTERING PEELING CONCRETE

Properties (6)

custom_field_three
LONG CIRCUM REBAR CORRODED & MISSING
custom_field_two
1
customer
LACSD
datetime
2021-09-16T00:30:59-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false