Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2021, 07:29 AM
  • G 0113_G 0086_9162021_005727.mp4

Date
09/16/2021
W/O
0901312
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P02174
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1943
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20210913MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0113
Downstream MH
G 0086
Dir. of Survey
Downstream
Length Surveyed
322.8 ft.
Total Length
322.8 ft.
Structural Index
5
Structural Quick
5841
Structural Rating
46
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
50
Pipe schematic from manhole G 0113 to G 0086
MH: G 0113MH: G 0086downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM0 ft. MWM - Water Mark, 60 %of cross sectional area2 ft. MGO - General Observation - 100% MISSING TILES2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING14.9 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CORRISON BEYOND REBAR30.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM60.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONGT CIRCUM REBAR CORRODED MISSING83.3 ft. MGO - General Observation - 8 TILES IN PLACE129 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR161.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN HANGING REBAR189.9 ft. MGO - General Observation - 30% TILES IN PLACE START214.9 ft. MGO - General Observation - 30% TILES IN PLACE FINISH238.7 ft. MGP - General Photograph - HANGING REBAR267.5 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR278.3 ft. MGO - General Observation - 12 TILES IN PLACE322.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG322.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - CORRISON BEYOUND REBAR322.2 ft. MGO - General Observation - TILES 100% MISSING322.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR CORRODED MISSING322.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE322.8 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (13)

  • General Observation - 100% MISSING TILES

    2 ft. - General Observation - 100% MISSING TILES

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING

    2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING

    8 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR MISSING

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CORRISON BEYOND REBAR

    14.9 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CORRISON BEYOND REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM

    30.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONGT CIRCUM REBAR CORRODED MISSING

    60.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONGT CIRCUM REBAR CORRODED MISSING

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR

    129 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN HANGING REBAR

    161.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN HANGING REBAR

  • General Observation - 30% TILES IN PLACE START

    189.9 ft. - General Observation - 30% TILES IN PLACE START

  • General Photograph - HANGING REBAR

    238.7 ft. - General Photograph - HANGING REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    267.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

Observations (25)

DistanceCodeObservation
8SRCLONG CIRCUM REBAR MISSING
129SRCCORRISON BEYOUND REBAR
322.2SAMSEVERE AGG
83.3MGO8 TILES IN PLACE
238.7MGPHANGING REBAR
322.2SRCCORRISON BEYOUND REBAR
2MGO100% MISSING TILES
0MWL
60.5SRCLONGT CIRCUM REBAR CORRODED MISSING
189.9MGO30% TILES IN PLACE START
322.2MGOTILES 100% MISSING
322.8AMH1:35AM
0AMH12:55AM
0MWM
278.3MGO12 TILES IN PLACE
267.5SRCLONG CIRCUM REBAR
322.2SRCLONG CIRCUM REBAR CORRODED MISSING
2SAMSEVERE AGG
214.9MGO30% TILES IN PLACE FINISH
30.1SRCCIRCUM
14.9SRCCORRISON BEYOND REBAR
2SSSBLISTERING PEELING CONCRETE
322.2SSSBLISTERING PEELING CONCRETE
2SRCLONG CIRCUM REBAR CORRODED & MISSING
161.2SRCBROKEN HANGING REBAR

Properties (6)

custom_field_three
LONG CIRCUM REB MISSING -CORRISON BEYOUND REBAR
custom_field_two
1
customer
LACSD
datetime
2021-09-16T00:29:36-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false