Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2021, 02:54 PM
  • H 1059_H 0967_08172021_080314.mp4

Date
08/17/2021
W/O
906779
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01005
PipeID
P15381
Time
7:54 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9255
Sewer Name
H JOINT OUTFALL H - UNIT 7C
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_906779_TV21087_AUG2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
H 1059
Downstream MH
H 0967
Dir. of Survey
Downstream
Length Surveyed
11.9 ft.
Total Length
11.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 1059 to H 0967
MH: H 1059MH: H 0967downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/RLF LINE0 ft. AMH - Upstream Manhole, Survey Begins - H 10590 ft. MWL - Water Level, 15 %of cross sectional area5.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish9.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE11.9 ft. AMH - Downstream Manhole, Survey Ends - H 0967

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
9.6SAV
0MWM
5.3SAV
0MGOCONN @ MH 3 O'CLOCK/RLF LINE
0AMHH 1059
11.9AMHH 0967
0MWL
9.6MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
630138081721021
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-08-17T07:54:23-07:00
documentation
PROPIPE
is_lateral_inspection
false