- Date
- 08/02/2021
- W/O
- 906776
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00261
- PipeID
- P04445
- Time
- 11:47 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9213
- Sewer Name
- 02 FOSTER ROAD TRUNK
- City
- DOWNEY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- WO_906776_TV02290_AUG2021
- Sewer Type
- Siphon
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 15 in.
- Upstream MH
- 02 2171
- Downstream MH
- 02 2170
- Dir. of Survey
- Downstream
- Length Surveyed
- 18.1 ft.
- Total Length
- 18.1 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2300
- O&M Rating
- 6
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole 02 2171 to 02 2170 Observation photos (3)

0 ft. - General Observation - COCKROACHES IN MANHOLE

10.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

18.1 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.