Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2021, 07:41 AM
  • 02 2169_02 2168_08032021_005728.mp4

Date
08/03/2021
W/O
906776
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00261
PipeID
P04443
Time
12:41 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9213
Sewer Name
02 FOSTER ROAD TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_906776_TV02290_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
18 in.
Upstream MH
02 2169
Downstream MH
02 2168
Dir. of Survey
Downstream
Length Surveyed
460.3 ft.
Total Length
460.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412U
O&M Rating
228
Overall Index
2
Overall Quick
Overall Rating
228
Pipe schematic from manhole 02 2169 to 02 2168
MH: 02 2169MH: 02 2168downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 21692 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start353 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS457.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish457.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish460.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE460.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK460.3 ft. AMH - Downstream Manhole, Survey Ends - 02 2168

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    460.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
457.2DAGS
460.3MGOCOCKROACHES IN MANHOLE
460.3MGOCONNECTION AT MH 3 O'CLOCK
353DSZDEBRIS
457.2DSZ
460.3AMH02 2168
2DAGS
0MWM
0MWL
0AMH02 2169

Properties (8)

additional_info
630069080221201
custom_field_three
DEBRIS
custom_field_two
3
customer
1
datetime
2021-08-03T00:41:23-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31114