Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2021, 08:46 AM
  • 02 2167_02 2166_08032021_015947.mp4

Date
08/03/2021
W/O
906776
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00261
PipeID
P04441
Time
1:46 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9213
Sewer Name
02 FOSTER ROAD TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
33
Purpose
Routine Assessment
Project
WO_906776_TV02290_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
18 in.
Upstream MH
02 2167
Downstream MH
02 2166
Dir. of Survey
Downstream
Length Surveyed
440.8 ft.
Total Length
440.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
413D
O&M Rating
250
Overall Index
2
Overall Quick
Overall Rating
250
Pipe schematic from manhole 02 2167 to 02 2166
MH: 02 2167MH: 02 2166downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 21670 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start167.9 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS286.3 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish438.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish440.8 ft. AMH - Downstream Manhole, Survey Ends - 02 2166

Observation photos (2)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0AMH02 2167
286.3DSZ
0MWM
0MGOCOCKROACHES IN MANHOLE
167.9DSZDEBRIS
2DAGS
0MWL
440.8AMH02 2166
438.1DAGS

Properties (8)

additional_info
630069080221201
custom_field_three
DEBRIS
custom_field_two
3
customer
1
datetime
2021-08-03T01:46:37-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31114