Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2021, 08:15 AM
  • 05 0859_05 0858_08172021_015729.mp4

Date
08/17/2021
W/O
906379
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00457
PipeID
P06089
Time
1:15 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9322
Sewer Name
05 IMPERIAL HIGHWAY EXTENSION TRUNK
City
LENNOX
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_906379_TV05334_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
05 0858
Downstream MH
05 0859
Dir. of Survey
Upstream
Length Surveyed
67.7 ft.
Total Length
67.7 ft.
Structural Index
3
Structural Quick
4628
Structural Rating
40
O&M Index
4
O&M Quick
4534
O&M Rating
32
Overall Index
3
Overall Quick
Overall Rating
72
Pipe schematic from manhole 05 0858 to 05 0859
MH: 05 0858MH: 05 0859upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 08590 ft. MGO - General Observation - UNABLE TO SETUP AT U/S MH (NEEDS MAJOR TRAFFIC CONTROL).0.6 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish0.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.6 ft. MCU - Camera Underwater, Finish19.2 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start24 ft. MCU - Camera Underwater, Start - DUE TO OFFSET JOINT35.5 ft. MMC - Material Change, Not know35.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start35.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish40.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"55.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"57 ft. JOL - Joint Offset Large59.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"60.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"64.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start67.7 ft. MWL - Water Level, 5 %of cross sectional area67.7 ft. AMH - Downstream Manhole, Survey Begins - 05 085867.7 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (9)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    7.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    7.8 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Joint Offset Large

    10.7 ft. - Joint Offset Large

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    32.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    32.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

  • Camera Underwater, Start - DUE TO OFFSET JOINT

    43.7 ft. - Camera Underwater, Start - DUE TO OFFSET JOINT

  • Deposits Settled Other,  20 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    48.5 ft. - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Upstream Manhole, Survey Ends - 05 0859

    67.7 ft. - Upstream Manhole, Survey Ends - 05 0859

Observations (19)

DistanceCodeObservation
43.7MCUDUE TO OFFSET JOINT
3.6FM
32.2MMC
11.8TF
0MWL
27.2TFC
7.1TB
67.1DSZ
32.2SSS
0AMH05 0858
32.2FM
48.5DSZ
67.1SSS
67.7AMH05 0859
0MWM
67.1MCU
7.8TB
67.7MGOUNABLE TO SETUP AT U/S MH (NEEDS MAJOR TRAFFIC CONTROL).
10.7JOL

Properties (7)

additional_info
630074081621202
custom_field_three
FRACTURE'S/LARGE OFFSET JOINT
custom_field_two
2
customer
1
datetime
2021-08-17T01:15:21-07:00
documentation
PROPIPE
is_lateral_inspection
false