Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2021, 08:23 AM
  • 01 0206_01 0205_08252021_014505.mp4

Date
08/25/2021
W/O
906567
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01248
Time
1:23 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9332
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_906568_TV01262_AUG2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0206
Downstream MH
01 0205
Dir. of Survey
Downstream
Length Surveyed
337.3 ft.
Total Length
337.3 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
195
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
195
Pipe schematic from manhole 01 0206 to 01 0205
MH: 01 0206MH: 01 0205downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02060 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES38.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"134.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"165 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"203.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"217.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"263.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"266.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"316.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"318.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES318.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish318.7 ft. MMC - Material Change, Vitrified clay pipe337.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK337.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0205

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    11 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    318.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Material Change, Vitrified clay pipe

    318.7 ft. - Material Change, Vitrified clay pipe

Observations (23)

DistanceCodeObservation
38.4TF
337.3MGOCONNECTION AT THE MH 3 OC'LOCK
165TF
11FM
82.1TF
0MWM
217.3TF
316.2TF
337.3AMH01 0205
2.1SAV
0MWL
0AMH01 0206
263.8TF
266.6TF
255.7TF
75.3TF
318.7CL
318.7SAV
117.9TF
318.7MMC
134.1TF
0MGOCONNECTION AT THE MH 9 OC'LOCK
203.6TF

Properties (7)

additional_info
630074082421202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2021-08-25T01:23:36-07:00
documentation
PROPIPE
is_lateral_inspection
false