- Date
- 09/10/2021
- W/O
- 0906263
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00221
- PipeID
- P01831
- Time
- 3:31 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1939
- Sewer Name
- 01 VERNON EXTENSION TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210910MDM_VERON_EXTENSION_TRUNK
- Material
- CIP
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 01 0991
- Downstream MH
- 01 0990
- Dir. of Survey
- Downstream
- Length Surveyed
- 313.2 ft.
- Total Length
- 313.2 ft.
- Structural Index
- 2
- Structural Quick
- 342B
- Structural Rating
- 42
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 42
Pipe schematic from manhole 01 0991 to 01 0990 Observation photos (7)

33.6 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT

88.7 ft. - General Observation - 24" CIP

257.9 ft. - General Observation - PIPE LOOKS LIKE VCP

287.5 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 50% METAL LOSS

287.5 ft. - Material Change, Cast Iron

290.4 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: NO - 50% METAL LOSS

300.4 ft. - Surface Corrosion Metal Pipe, from 08 to 11 o'clock, within 8 inches of joint: NO - 50% METAL LOSS