Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2021, 07:54 AM
  • 30 0280_30 0368_982021_030921.mp4

Date
09/08/2021
W/O
0880029
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00875
PipeID
P21449
Time
12:54 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1936
Sewer Name
30 MALAGA COVE P.P. #2 INFLUENT SEWER
City
PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20210908MDM_MALGA_COVE_P_P_2_INFLUENT_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
9.5 in.
Upstream MH
30 0280
Downstream MH
30 0368
Dir. of Survey
Downstream
Length Surveyed
24.8 ft.
Total Length
24.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 30 0280 to 30 0368
MH: 30 0280MH: 30 0368downstream0 ft. MWL - Water Level, 70 %of cross sectional area0 ft. MWM - Water Mark, 90 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active8 ft. MGO - General Observation - 9.5' VCP-CIPP LINER8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start8 ft. LFZ - Lining Failure Other, from 04 to 08 o'clock, within 8 inches of joint: NO, Start - TORN LINER9.3 ft. MGO - General Observation - TORN LINER9.3 ft. MGO - General Observation - TORN LINER20.2 ft. MGO - General Observation - TORN LINER24.1 ft. LFZ - Lining Failure Other, from 04 to 08 o'clock, within 8 inches of joint: NO, Finish - TORN LINER24.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish24.8 ft. AMH - Downstream Manhole, Survey Ends - 2:55AM

Observation photos (6)

  • General Observation - 9.5' VCP-CIPP LINER

    8 ft. - General Observation - 9.5' VCP-CIPP LINER

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Lining Failure Other, from 04 to 08 o'clock, within 8 inches of joint: NO, Start - TORN LINER

    8 ft. - Lining Failure Other, from 04 to 08 o'clock, within 8 inches of joint: NO, Start - TORN LINER

  • General Observation - TORN LINER

    9.3 ft. - General Observation - TORN LINER

  • General Observation - TORN LINER

    9.3 ft. - General Observation - TORN LINER

  • General Observation - TORN LINER

    20.2 ft. - General Observation - TORN LINER

Observations (13)

DistanceCodeObservation
24.1LFZTORN LINER
9.3MGOTORN LINER
0MWL
9.3MGOTORN LINER
0MWM
8MGO9.5' VCP-CIPP LINER
24.8AMH2:55AM
0AMH1:55AM
24.1DAGS
0MGOConn. @ Mh, 3 O' Clock. Active
20.2MGOTORN LINER
8DAGS
8LFZTORN LINER

Properties (7)

custom_field_three
TORN LINER BOTTOM OF PIPE
custom_field_two
2
customer
LACSD
datetime
2021-09-08T00:54:42-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
CIPP