Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2021, 07:57 AM
  • 18 0828A_18 0828_08032021_011007.mp4

Date
08/03/2021
W/O
906773
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00707
PipeID
P14692
Time
12:57 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8697
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_906773_TV18113_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0828
Downstream MH
18 0828A
Dir. of Survey
Upstream
Length Surveyed
152.5 ft.
Total Length
152.5 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 18 0828 to 18 0828A
MH: 18 0828MH: 18 0828Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 0828A1.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.7 ft. MGO - General Observation - ABANDONED MH15.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"18.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.4 ft. MGO - General Observation - UNMAPPED MH147 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start148.2 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"149.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO152.5 ft. AMH - Downstream Manhole, Survey Begins - 18 0828152.5 ft. MWL - Water Level, 10 %of cross sectional area152.5 ft. MGO - General Observation - MH IS ABANDONED152.5 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: NO

    2.8 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO

  • Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"

    4.3 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0AMH18 0828
150.8FM
150.8MGOABANDONED MH
85.3TFC
134.2TFC
152.5AMH18 0828A
136.9TFC
2.8DAGS
0MWL
5.5FM
88.1TFC
0MGOMH IS ABANDONED
48.1MGOUNMAPPED MH
4.3TBA
0MWM

Properties (7)

additional_info
630138080221202
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-08-03T00:57:27-07:00
documentation
PROPIPE
is_lateral_inspection
false