Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2021, 06:51 AM
  • 18 0823_18 0822_08032021_001420.mp4

Date
08/02/2021
W/O
906773
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00707
PipeID
P14686
Time
11:51 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8697
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_906773_TV18113_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0823
Downstream MH
18 0822
Dir. of Survey
Downstream
Length Surveyed
322.3 ft.
Total Length
322.3 ft.
Structural Index
4
Structural Quick
4631
Structural Rating
27
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
31
Pipe schematic from manhole 18 0823 to 18 0822
MH: 18 0823MH: 18 0822downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08232.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"22 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES60.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"68 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"118.1 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"120.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"124.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES168.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"219.7 ft. FM - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES221.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"242.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"244.1 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES269.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"280.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES301.4 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4"308.5 ft. FM - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES320.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish320.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish322.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0822

Observation photos (8)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    22 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    124.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    219.7 ft. - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    244.1 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    280.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    308.5 ft. - Fracture Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
0MWL
320.3CM
2.5DAGS
68TBC
269.6TB
322.3AMH18 0822
242.3TB
60.6TB
168.9TB
0MWM
301.4TB
280.2FM
0AMH18 0823
308.5FM
181.8TB
5.9CM
244.1FM
120.9TB
22FM
19.6TB
221.3TB
124.3FM
118.1TBA
219.7FM
320.3DAGS

Properties (7)

additional_info
630138080221202
custom_field_three
CRACKS, FRACTURES
custom_field_two
2
customer
1
datetime
2021-08-02T23:51:54-07:00
documentation
PROPIPE
is_lateral_inspection
false