- Date
- 08/03/2021
- W/O
- 906773
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00707
- PipeID
- P14685
- Time
- 11:06 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9220
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECT 5
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- WO_906773_TV18113_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 0821
- Downstream MH
- 18 0822
- Dir. of Survey
- Upstream
- Length Surveyed
- 83.7 ft.
- Total Length
- 83.7 ft.
- Structural Index
- 4
- Structural Quick
- 4232
- Structural Rating
- 14
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole 18 0821 to 18 0822 Observation photos (4)

6.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

17.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

45.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

49.5 ft. - Fracture Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES