Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 4, 2021, 09:00 AM
  • 18 0813_18 0812_08042021_020821.mp4

Date
08/04/2021
W/O
906773
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00707
PipeID
P14676
Time
2:00 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9220
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_906773_TV18113_AUG2021
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0813
Downstream MH
18 0812
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole 18 0813 to 18 0812
MH: 18 0813MH: 18 0812downstream0 ft. MWL - Water Level, 60 %of cross sectional area - UNDER GREASE0 ft. AMH - Upstream Manhole, Survey Begins - 18 08130 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. DSZ - Deposits Settled Other, 30 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES - MIXTURE OF DEBRIS2 ft. MGO - General Observation - NW BARREL2.1 ft. MSA - Survey Abandoned - VIEW OF SIPHON DOWNLEG

Observation photos (1)

  • Deposits Settled Other,  30 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES - MIXTURE OF DEBRIS

    2 ft. - Deposits Settled Other, 30 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES - MIXTURE OF DEBRIS

Observations (6)

DistanceCodeObservation
0MWLUNDER GREASE
0AMH18 0813
2.1MSAVIEW OF SIPHON DOWNLEG
2DSZMIXTURE OF DEBRIS
0MWM
2MGONW BARREL

Properties (7)

additional_info
630138080321201
custom_field_three
NO STRUCTRUAL DEFECTS
custom_field_two
4
customer
1
datetime
2021-08-04T02:00:59-07:00
documentation
PROPIPE
is_lateral_inspection
false