Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 18, 2021, 04:26 AM
  • 05 1393_05 1392_08172021_214636.mp4

Date
08/17/2021
W/O
906612
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06614
Time
9:26 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9324
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_906612_TV05336_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
18 in.
Upstream MH
05 1393
Downstream MH
05 1392
Dir. of Survey
Downstream
Length Surveyed
275.4 ft.
Total Length
275.4 ft.
Structural Index
4
Structural Quick
4J00
Structural Rating
216
O&M Index
2
O&M Quick
2800
O&M Rating
16
Overall Index
4
Overall Quick
Overall Rating
232
Pipe schematic from manhole 05 1393 to 05 1392
MH: 05 1393MH: 05 1392downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13930 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start38.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"83 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"137.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES137.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"138.4 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start171.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish186 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"238 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"275.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1392275.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish275.4 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK275.4 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED

Observation photos (3)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    137.2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Grease, 10 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    138.4 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
0AMH05 1393
138.4DAGS
275.4AMH05 1392
186TFC
275.4FM
171.3DAGS
275.4MGOCONNECTION AT THE MH 3 OC'LOCK
38.5TF
3.1FM
0MWM
238TFC
137.3TFA
137.2DAGS
83TFC
275.4MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
0MWL

Properties (7)

additional_info
630074081721201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-08-17T21:26:51-07:00
documentation
PROPIPE
is_lateral_inspection
false