Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2021, 10:11 AM
  • 05 1295_05 1378_08172021_032106.mp4

Date
08/17/2021
W/O
906612
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06598
Time
3:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9323
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_906612_TV05336_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1295
Downstream MH
05 1378
Dir. of Survey
Downstream
Length Surveyed
31.4 ft.
Total Length
31.4 ft.
Structural Index
3
Structural Quick
4136
Structural Rating
22
O&M Index
3
O&M Quick
3400
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
34
Pipe schematic from manhole 05 1295 to 05 1378
MH: 05 1295MH: 05 1378downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 12950 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area3.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8.9 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start24 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES31.4 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Finish31.4 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK31.4 ft. AMH - Downstream Manhole, Survey Ends - 05 137831.4 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK31.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  20 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: NO, Start

    8.9 ft. - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    24 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0MGOCONNECTION AT THE MH 3 OC'LOCK
31.4DSZ
31.4MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH05 1295
0MWM
3.2CM
31.4AMH05 1378
8.9DSZ
0MWL
31.4MGOCONNECTION AT THE MH 9 OC'LOCK
31.4CM
24FM

Properties (7)

additional_info
630074081621203
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-08-17T03:11:12-07:00
documentation
PROPIPE
is_lateral_inspection
false