Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 3, 2021, 05:17 AM
  • 18 0826_18 0825_08022021_223845.mp4

Date
08/02/2021
W/O
906569
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00707
PipeID
P14689
Time
10:17 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8696
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_906569_TV18119_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0826
Downstream MH
18 0825
Dir. of Survey
Downstream
Length Surveyed
240.7 ft.
Total Length
240.7 ft.
Structural Index
3
Structural Quick
4333
Structural Rating
23
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole 18 0826 to 18 0825
MH: 18 0826MH: 18 0825downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08265.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES6.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES9.8 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES12.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.7 ft. FM - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES32.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"35.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"44 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES65.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"116.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"166.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"169.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"216 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"238.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish238.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish240.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK240.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0825

Observation photos (7)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    5.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    6.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    9.8 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    31.7 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    44 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    65.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
238.7FM
12.9CM
70.3TFC
31.7FM
5.1CM
216TFC
65.7FM
166.4TF
6.7CL
240.7MGOCONNECTION AT MH 3 O'CLOCK
44FM
219.1TFC
116.7TFC
9.8CM
240.7AMH18 0825
238.7CM
0MWM
35.7TFC
0MGOCONNECTION AT MH 3 O'CLOCK
32.6TF
0MWL
169.4TF
0AMH18 0826
113.6TFC

Properties (7)

additional_info
630138080221201
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-08-02T22:17:50-07:00
documentation
PROPIPE
is_lateral_inspection
false