- Date
- 08/02/2021
- W/O
- 906569
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00707
- PipeID
- P14688
- Time
- 10:43 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8696
- Sewer Name
- 18 SO WHITTIER OUTFALL TR, SECT 5
- City
- SANTA FE SPRINGS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906569_TV18119_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0825
- Downstream MH
- 18 0824
- Dir. of Survey
- Downstream
- Length Surveyed
- 128.3 ft.
- Total Length
- 128.3 ft.
- Structural Index
- 3
- Structural Quick
- 4134
- Structural Rating
- 16
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 18 0825 to 18 0824 Observation photos (6)

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

5.1 ft. - Fracture Spiral, from 03 to 08 o'clock, within 8 inches of joint: YES

8.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

11.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

14.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

17.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start