Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 4, 2021, 10:08 AM
  • 18 0812_18 0783_08042021_032839.mp4

Date
08/04/2021
W/O
906569
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00707
PipeID
P14675
Time
3:08 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9219
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_906569_TV18119_AUG2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0812
Downstream MH
18 0783
Dir. of Survey
Downstream
Length Surveyed
199.9 ft.
Total Length
199.9 ft.
Structural Index
4
Structural Quick
5444
Structural Rating
48
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
50
Pipe schematic from manhole 18 0812 to 18 0783
MH: 18 0812MH: 18 0783downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08122.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start12.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES24.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES36.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start80.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES84 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES87.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start123.2 ft. B - Broken, from 03 to 05 o'clock, within 8 inches of joint: YES127 ft. FH3 - Fracture Longitudinal Hinge, 3, from 09 to 03 o'clock, within 8 inches of joint: YES, Start134.9 ft. FH3 - Fracture Longitudinal Hinge, 3, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish142.4 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES150.8 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish181.8 ft. B - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES, Start194.6 ft. B - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish196.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish196.6 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES196.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish199.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0783199.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (13)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

    2.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: NO - AT MOUTH OF PIPE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    12.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    24.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    36.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    80.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    84 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    87.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 03 to 05 o'clock, within 8 inches of joint: YES

    123.2 ft. - Broken, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal Hinge, 3, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    127 ft. - Fracture Longitudinal Hinge, 3, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

    142.4 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    181.8 ft. - Broken, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    196.6 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
196.6FM
24.3CM
2.1CMAT MOUTH OF PIPE
123.2B
181.8B
196.6FM
2.1DAGS
12.5CM
0MWL
194.6B
127FH3
0MWM
199.9AMH18 0783
150.8B
0AMH18 0812
84FM
87.2FM
196.6CM
142.4B
134.9FH3
199.9DAGS
36.3CM
80.2FM

Properties (7)

additional_info
630138080321202
custom_field_three
BROKEN PIPE, SEVERE FRACTURES
custom_field_two
1
customer
1
datetime
2021-08-04T03:08:29-07:00
documentation
PROPIPE
is_lateral_inspection
false