- Date
- 08/10/2021
- W/O
- 906778
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00790
- PipeID
- P17350
- Time
- 9:47 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9112
- Sewer Name
- 22 BASE LINE TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906778_TV22176_AUG2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0980
- Downstream MH
- 22 0979
- Dir. of Survey
- Downstream
- Length Surveyed
- 302.6 ft.
- Total Length
- 302.6 ft.
- Structural Index
- 4
- Structural Quick
- 4131
- Structural Rating
- 7
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 22 0980 to 22 0979 Observation photos (3)

8.9 ft. - Fracture Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES

181.4 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

253 ft. - Fracture Multiple, from 08 to 02 o'clock, within 8 inches of joint: YES