Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2021, 08:48 AM
  • 22 0960_22 0959_08102021_021500.mp4

Date
08/10/2021
W/O
906375
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00790
PipeID
P17330
Time
1:48 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9111
Sewer Name
22 BASE LINE TRUNK
City
GLENDORA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_906375_TV22002_AUG2021
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0960
Downstream MH
22 0959
Dir. of Survey
Downstream
Length Surveyed
440.1 ft.
Total Length
440.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 22 0960 to 22 0959
MH: 22 0960MH: 22 0959downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 09600 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. MGO - General Observation - MAG COAT26.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS67.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS115.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS119.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS167.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS220.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS245.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS268.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS318 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS366.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS375.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS419.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6" - DEBRIS438.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish438.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish440.1 ft. AMH - Downstream Manhole, Survey Ends - 22 0959

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2.3 ft. - General Observation - MAG COAT

Observations (22)

DistanceCodeObservation
438.7SAV
220.7TFDEBRIS
268.8TFDEBRIS
119.6TFDEBRIS
2.3SAV
419.8TFCDEBRIS
0AMH22 0960
0MWL
67.2TFDEBRIS
245.5TFDEBRIS
0MWM
440.1AMH22 0959
2.3SSS
375.2TFCDEBRIS
167.9TFDEBRIS
366.7TFDEBRIS
0MGOCONNECTION AT MH 9 O'CLOCK
318TFDEBRIS
2.3MGOMAG COAT
115.7TFDEBRIS
438.7SSS
26.3TFDEBRIS

Properties (7)

additional_info
630138080921201
custom_field_three
SPALLING, AGGREGATE VISIBLE, MAG COAT
custom_field_two
3
customer
1
datetime
2021-08-10T01:48:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false