- Date
- 08/10/2021
- W/O
- 906375
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00790
- PipeID
- P17328
- Time
- 3:11 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9111
- Sewer Name
- 22 BASE LINE TRUNK
- City
- GLENDORA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_906375_TV22002_AUG2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0958
- Downstream MH
- 22 0957
- Dir. of Survey
- Downstream
- Length Surveyed
- 442.8 ft.
- Total Length
- 442.8 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 22 0958 to 22 0957 Observation photos (3)

2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

354.7 ft. - Alignment Right, 10 %, Start

395.7 ft. - Alignment Right, 15 %, Start