Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2021, 03:40 PM
  • 29 0750_29 0749_07262021_085355.mp4

Date
07/26/2021
W/O
901245
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01090
PipeID
P24388
Time
8:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9084
Sewer Name
29 ALAMITOS PUMPING PLANT SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_901245_TV29013_JUL2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0749
Downstream MH
29 0750
Dir. of Survey
Upstream
Length Surveyed
207.2 ft.
Total Length
207.2 ft.
Structural Index
2
Structural Quick
2G00
Structural Rating
82
O&M Index
2
O&M Quick
2G00
O&M Rating
82
Overall Index
2
Overall Quick
Overall Rating
164
Pipe schematic from manhole 29 0749 to 29 0750
MH: 29 0749MH: 29 0750upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 07502.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish8.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN29.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN61.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN82.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN121 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN135.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN162.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN189 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN205.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start205.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start207.2 ft. MWM - Water Mark, 5 %of cross sectional area207.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0749207.2 ft. MWL - Water Level, 5 %of cross sectional area

Observations (16)

DistanceCodeObservation
207.2AMH29 0750
205SSS
44.8TFOPEN
198.4TFOPEN
0MWM
86.2TFOPEN
2DAGS
0AMH29 0749
145.3TFOPEN
2SSS
205DAGS
0MWL
71.4TFOPEN
124.8TFOPEN
178TFOPEN
18.2TFOPEN

Properties (7)

additional_info
630074072621061
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2021-07-26T08:40:40-07:00
documentation
PROPIPE
is_lateral_inspection
false