Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2021, 06:54 AM
  • E 0038_E 0037_08122021_235908.mp4

Date
08/12/2021
W/O
906380
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00028
PipeID
P11265
Time
11:54 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9314
Sewer Name
E JOINT OUTFALL E - UNIT 2
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_906380_TV01123_AUG2021
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
E 0037
Downstream MH
E 0038
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole E 0037 to E 0038
MH: E 0037MH: E 0038upstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON0 ft. MGO - General Observation - MAG COAT0 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. AMH - Downstream Manhole, Survey Begins - E 00372.1 ft. MWM - Water Mark, 25 %of cross sectional area2.1 ft. MWL - Water Level, 25 %of cross sectional area

Observation photos (4)

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

    2.1 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    2.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
2.1MSAVIEW OF UPLEG OF D/S SIPHON
0AMHE 0037
0MWM
0MWL
2.1MGOMAG COAT
2.1SRV
2.1SSS
2.1SAV

Properties (7)

additional_info
630074081221201
custom_field_three
AGGREGATE VISIBLE/SPALLING/REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2021-08-12T23:54:54-07:00
documentation
PROPIPE
is_lateral_inspection
false